DATADIGITAL-SVR Series Static Voltage Stabilizers
Full digital microprocessor controlled
thyristor tap changer
20 millisecond response, 5000 volts / second correction speed
Over current and voltage (peak, surge) under voltage, output short circuit protection
True RMS-True effective measuring and display order
Wide range of input voltages (80-270VAC) (110-270VAC) (130-260VAC)
İzolation Transformer (Optional)
RS 232, ETHERNET ve MOD-BUS with remote monitoring (Optional)
Manual By-Pass, Auto By-Pass (Optional)
Unconditional 2-year Warranty
10 Year Parts Availability Guarantee
ISO9001-2008 Production with quality management system
Technicial Specifications
Power | 30kVA |
Operating Voltage | 380VAC -%40 /+ %25 ( 225-470VAC ) |
Input Voltage Range | 380VAC -%20 /+ %20 ( 300-450VAC ) |
Output Voltage | 380VAC -/+ %1~3 |
Operating Current | Output I Max; 45A |
Operating Frequency | 50 Hz -/+ %5 |
Correction Speed | 5000 volt. / second |
Response Speed | 20 Millisecond |
Control | DSPIC Control, Thyristor tap Changer, Zero Current Transfer |
Protection | Passive and electronic protection (overvoltage and current, undervoltage protection) |
Dimensions (AxBxC) [cm] |
40x60x70 / 110KG |
Power | 45kVA |
Operating Voltage | 380VAC -%40 /+ %25 ( 225-470VAC ) |
Input Voltage Range | 380VAC -%20 /+ %20 ( 300-450VAC ) |
Output Voltage | 380VAC -/+ %1~3 |
Operating Current | Output I Max; 68A |
Operating Frequency | 50 Hz -/+ %5 |
Correction Speed | 5000 volt. / second |
Response Speed | 20 Millisecond |
Control | DSPIC Control, Thyristor tap Changer, Zero Current Transfer |
Protection | Passive and electronic protection (overvoltage and current, undervoltage protection) |
Dimensions (AxBxC) [cm] |
40x70x80 / 125KG |
Power | 75kVA |
Operating Voltage | 380VAC -%40 /+ %25 ( 225-470VAC ) |
Input Voltage Range | 380VAC -%20 /+ %20 ( 300-450VAC ) |
Output Voltage | 380VAC -/+ %1~3 |
Operating Current | Output I Max; 115A |
Operating Frequency | 50 Hz -/+ %5 |
Correction Speed | 5000 volt. / second |
Response Speed | 20 Millisecond |
Control | DSPIC Control, Thyristor tap Changer, Zero Current Transfer |
Protection | Passive and electronic protection (overvoltage and current, undervoltage protection) |
Dimensions (AxBxC) [cm] |
46x50x115 / 225KG |
Power | 100kVA |
Operating Voltage | 380VAC -%40 /+ %25 ( 225-470VAC ) |
Input Voltage Range | 380VAC -%20 /+ %20 ( 300-450VAC ) |
Output Voltage | 380VAC -/+ %1~3 |
Operating Current | Output I Max; 150A |
Operating Frequency | 50 Hz -/+ %5 |
Correction Speed | 5000 volt. / second |
Response Speed | 20 Millisecond |
Control | DSPIC Control, Thyristor tap Changer, Zero Current Transfer |
Protection | Passive and electronic protection (overvoltage and current, undervoltage protection) |
Dimensions (AxBxC) [cm] |
50x60x135 / 280KG |
Power | 200kVA |
Operating Voltage | 380VAC -%40 /+ %25 ( 225-470VAC ) |
Input Voltage Range | 380VAC -%20 /+ %20 ( 300-450VAC ) |
Output Voltage | 380VAC -/+ %1~3 |
Operating Current | Output I Max; 300A |
Operating Frequency | 50 Hz -/+ %5 |
Correction Speed | 5000 volt. / second |
Response Speed | 20 Millisecond |
Control | DSPIC Control, Thyristor tap Changer, Zero Current Transfer |
Protection | Passive and electronic protection (overvoltage and current, undervoltage protection) |
Dimensions (AxBxC) [cm] |
110x60x170 / 550KG |
Power | 300kVA |
Operating Voltage | 380VAC -%40 /+ %25 ( 225-470VAC ) |
Input Voltage Range | 380VAC -%20 /+ %20 ( 300-450VAC ) |
Output Voltage | 380VAC -/+ %1~3 |
Operating Current | Output I Max; 450A |
Operating Frequency | 50 Hz -/+ %5 |
Correction Speed | 5000 volt. / second |
Response Speed | 20 Millisecond |
Control | DSPIC Control, Thyristor tap Changer, Zero Current Transfer |
Protection | Passive and electronic protection (overvoltage and current, undervoltage protection) |
Dimensions (AxBxC) [cm] |
130x70x170 / 850KG |
Power | 400kVA |
Operating Voltage | 380VAC -%40 /+ %25 ( 225-470VAC ) |
Input Voltage Range | 380VAC -%20 /+ %20 ( 300-450VAC ) |
Output Voltage | 380VAC -/+ %1~3 |
Operating Current | Output I Max; 600A |
Operating Frequency | 50 Hz -/+ %5 |
Correction Speed | 5000 volt. / second |
Response Speed | 20 Millisecond |
Control | DSPIC Control, Thyristor tap Changer, Zero Current Transfer |
Protection | Passive and electronic protection (overvoltage and current, undervoltage protection) |
Dimensions (AxBxC) [cm] |
130x80x170 / 1000KG |
Power | 500kVA |
Operating Voltage | 380VAC -%40 /+ %25 ( 225-470VAC ) |
Input Voltage Range | 380VAC -%20 /+ %20 ( 300-450VAC ) |
Output Voltage | 380VAC -/+ %1~3 |
Operating Current | Output I Max; 750A |
Operating Frequency | 50 Hz -/+ %5 |
Correction Speed | 5000 volt. / second |
Response Speed | 20 Millisecond |
Control | DSPIC Control, Thyristor tap Changer, Zero Current Transfer |
Protection | Passive and electronic protection (overvoltage and current, undervoltage protection) |
Dimensions (AxBxC) [cm] |
140x80x170 / 1150KG |
Power | 600kVA |
Operating Voltage | 380VAC -%40 /+ %25 ( 225-470VAC ) |
Input Voltage Range | 380VAC -%20 /+ %20 ( 300-450VAC ) |
Output Voltage | 380VAC -/+ %1~3 |
Operating Current | Output I Max; 900A |
Operating Frequency | 50 Hz -/+ %5 |
Correction Speed | 5000 volt. / second |
Response Speed | 20 Millisecond |
Control | DSPIC Control, Thyristor tap Changer, Zero Current Transfer |
Protection | Passive and electronic protection (overvoltage and current, undervoltage protection) |
Dimensions (AxBxC) [cm] |
140x80x170 / 1300KG |
Power | 800kVA |
Operating Voltage | 380VAC -%40 /+ %25 ( 225-470VAC ) |
Input Voltage Range | 380VAC -%20 /+ %20 ( 300-450VAC ) |
Output Voltage | 380VAC -/+ %1~3 |
Operating Current | Output I Max; 1200A |
Operating Frequency | 50 Hz -/+ %5 |
Correction Speed | 5000 volt. / second |
Response Speed | 20 Millisecond |
Control | DSPIC Control, Thyristor tap Changer, Zero Current Transfer |
Protection | Passive and electronic protection (overvoltage and current, undervoltage protection) |
Dimensions (AxBxC) [cm] |
200x90x200 / 2000KG |
Power | 1000kVA |
Operating Voltage | 380VAC -%40 /+ %25 ( 225-470VAC ) |
Input Voltage Range | 380VAC -%20 /+ %20 ( 300-450VAC ) |
Output Voltage | 380VAC -/+ %1~3 |
Operating Current | Output I Max; 1500A |
Operating Frequency | 50 Hz -/+ %5 |
Correction Speed | 5000 volt. / second |
Response Speed | 20 Millisecond |
Control | DSPIC Control, Thyristor tap Changer, Zero Current Transfer |
Protection | Passive and electronic protection (overvoltage and current, undervoltage protection) |
Dimensions (AxBxC) [cm] |
200x90x200 / 2250KG |
Power | 1600kVA |
Operating Voltage | 380VAC -%40 /+ %25 ( 225-470VAC ) |
Input Voltage Range | 380VAC -%20 /+ %20 ( 300-450VAC ) |
Output Voltage | 380VAC -/+ %1~3 |
Operating Current | Output I Max; 2400A |
Operating Frequency | 50 Hz -/+ %5 |
Correction Speed | 5000 volt. / second |
Response Speed | 20 Millisecond |
Control | DSPIC Control, Thyristor tap Changer, Zero Current Transfer |
Protection | Passive and electronic protection (overvoltage and current, undervoltage protection) |
Dimensions (AxBxC) [cm] |
300x110x210 / 3900KG |
Power | 2000kVA |
Operating Voltage | 380VAC -%40 /+ %25 ( 225-470VAC ) |
Input Voltage Range | 380VAC -%20 /+ %20 ( 300-450VAC ) |
Output Voltage | 380VAC -/+ %1~3 |
Operating Current | Output I Max; 3000A |
Operating Frequency | 50 Hz -/+ %5 |
Correction Speed | 5000 volt. / second |
Response Speed | 20 Millisecond |
Control | DSPIC Control, Thyristor tap Changer, Zero Current Transfer |
Protection | Passive and electronic protection (overvoltage and current, undervoltage protection) |
Dimensions (AxBxC) [cm] |
300x110x210 / 4250KG |
Power | 2500kVA |
Operating Voltage | 380VAC -%40 /+ %25 ( 225-470VAC ) |
Input Voltage Range | 380VAC -%20 /+ %20 ( 300-450VAC ) |
Output Voltage | 380VAC -/+ %1~3 |
Operating Current | Output I Max; 4000A |
Operating Frequency | 50 Hz -/+ %5 |
Correction Speed | 5000 volt. / second |
Response Speed | 20 Millisecond |
Control | DSPIC Control, Thyristor tap Changer, Zero Current Transfer |
Protection | Passive and electronic protection (overvoltage and current, undervoltage protection) |
Dimensions (AxBxC) [cm] |
330x110x210 / 5750KG |
Power | 3500kVA |
Operating Voltage | 380VAC -%40 /+ %25 ( 225-470VAC ) |
Input Voltage Range | 380VAC -%20 /+ %20 ( 300-450VAC ) |
Output Voltage | 380VAC -/+ %1~3 |
Operating Current | Output I Max; 5000A |
Operating Frequency | 50 Hz -/+ %5 |
Correction Speed | 5000 volt. / second |
Response Speed | 20 Millisecond |
Control | DSPIC Control, Thyristor tap Changer, Zero Current Transfer |
Protection | Passive and electronic protection (overvoltage and current, undervoltage protection) |
Dimensions (AxBxC) [cm] |
500x130x230 / 9000KG |